K-FLEX AL CLAD SYSTEM
Technical specifications
TEMPERATURE RANGE
K-FLEX ST AL CLAD pipe: from -40 °C to +110 °C
K-FLEX ST AL CLAD sheet: from -40 °C to +85 °C
K-FLEX ECO AL CLAD pipe: from -40 °C to +150 °C
K-FLEX SOLAR AL CLAD pipe: from -40 °C to +150 °C
FIRE RATING
K-FLEX ST AL CLAD pipe: Euroclass CL-s3,d0 (with K-FLEX ST)
K-FLEX ST AL CLAD sheet: Euroclass D-s3,d0 (with K-FLEX ST)
K-FLEX ECO AL CLAD sheet: Euroclass E
K-FLEX ECO AL CLAD pipe: Euroclass DL-s2, d0
K-FLEX SOLAR AL CLAD pipe: Euroclass E
BS 476 p6 - class 0 (with K-FLEX ST)
WEIGHT
Approx. 388 g/m2 - EN 22 286
THICKNESS
Approx. 280 μm - DIN 53 370
TRACTION RESISTANCE LONGITUDINAL
175 N/15 mm - ISO 527- 3
TRACTION RESISTANCE TRANSVERSE
175 N/15 mm - ISO 527- 3
BREAKING STRAIN LONGITUDINAL
35 % - ISO 527- 3
BREAKING STRAIN TRANSVERSE
40 % - ISO 527- 3
RESISTANCE TO TEARING LONGITUDINAL
155 N/25 mm - ISO 527- 3
RESISTANCE TO TEARING TRANSVERSE
182 N/25 mm - ISO 527- 3
RESISTANCE TO BENDING LONGITUDINAL
90 N/mm2 - DIN 53 864
RESISTANCE TO BENDING TRANSVERSE
90 N/mm2 - DIN 53 864
UV RESISTANCE
>2000 hours 500 W/m2 (Atlas Suntest XLS+ QUV, internal test)
RADIATION RESISTANCE
>3.600.000 kJ/m2
RESISTANCE TO HUMIDITY
>2000 hours UVC (internal test)
Contact us for more information about this product